Forum topic

3 posts / 0 new
Last post
valoriedunn
PIV

I had our PHD RN in oncology question PIV routine site rotations in the oncology/immune compromised patients. Her thought is if the implanted port Huber needle requires at least an every 7 day change shouldn't this population have at least an every 7 day PIV site rotation? Any ideas??? I am a firm believer in site rotation only when clinically indicated but her feeling is her population will not she signs of complication???

lynncrni
 See page S58 of INS

 See page S58 of INS Standards, Practice Criteria D. 3, there is no recommendation for changing the port access needle every 7 days. So this rationale does not hold up. Lynn

Lynn Hadaway, M.Ed., RN, BC, CRNI

Lynn Hadaway Associates, Inc.

126 Main Street, PO Box 10

Milner, GA 30257

Website http://www.hadawayassociates.com

Office Phone 770-358-7861

valoriedunn
 TY Lynn.  I knew you would

 TY Lynn.  I knew you would confirm my recommenation :)

Valorie Dunn,BSN, RN, CRNI, PLNC

Log in or register to post comments